Rescanning drives, Rescanning drives a-8 – Adaptec SATA AND SCSI RAID CONTROLLERS User Manual
Page 70

A-8
Adaptec RAID Configuration Utility (ARC)
To initialize drives:
1
Restart the computer, then press Ctrl+A when prompted to
access the ARC utility.
2
From the ARC menu, select Array Configuration Utility.
3
Select Initialize Drives.
4
Browse with the arrow keys to select a channel.
5
Browse with the arrow keys to highlight the disk you want to
initialize, then press Insert.
6
Repeat
until all the drives to be initialized are selected.
7
Press Enter.
8
Read the warning message, ensure that you have selected the
correct drives to initialize, and then press Y to continue.
Rescanning Drives
To rescan the drives connected to the controller:
1
Restart the computer, then press Ctrl+A when prompted to
access the ARC utility.
2
From the ARC menu, select Array Configuration Utility.
3
Select Rescan Drives.