beautypg.com

Sata configuration options, Sata configuration options a-12 – Adaptec SATA AND SCSI RAID CONTROLLERS User Manual

Page 74

background image

A-12

Adaptec RAID Configuration Utility (ARC)

SATA Configuration Options

The SATA Configuration options are described in the table below.

Option

Default

Models

Affected

Description

Write Cache

Yes

All SATA
controllers

When Enabled, write cache is enabled,
providing maximum performance.
Caution

—When Enabled, there is a

potential for data loss or corruption
during a power failure.

DMA

Yes

Adaptec
2410SA
only

When Enabled, Direct Memory Access
(DMA) mode is used for the drive,
providing maximum performance.

SMART

Yes

Adaptec
2410SA
only

Controls the predictive failure feature
of the drive. When Enabled and the
drive supports Self-Monitoring,
Analysis and Reporting Technology
(SMART) configuration, the SMART
status of the drive (Healthy or Failed)
is displayed along with the physical
drive display during POST. Messages
are logged to the Storage Manager log
file when they occur. When Event
Broadcasting is enabled for your
operating system, SMART events are
also sent to destinations according to
the system’s particular configuration
(for example, system log file, Event
Viewer, pop ups, email, etc.) When
Disabled, or when the drive does not
support SMART, the SMART status is
not displayed.

Allow Read
Ahead

Yes

Adaptec
2410SA
only

When Enabled, the drive’s read ahead
cache algorithm is use, providing
maximum performance under most
circumstances.