beautypg.com

Displaying array information, Displaying array information d-12 – Adaptec SATA AND SCSI RAID CONTROLLERS User Manual

Page 115

background image

D-12

Command Line Interface

Disk Show Defects

The disk show defects command shows the following types on
information:

Total number and location of primary defects (defects that
originate during manufacturing)

Total number and location of grown defects (defects that
originate after manufacturing)

Example

In the example below, the drive contains five primary defects and
no grown defects:

AAC0> disk show defects /full=true (0,1,0)
Executing: disk show defects /full=TRUE (CHANNEL=0,ID=1,LUN=0)
Number of PRIMARY defects on drive: 5
Defect 1 at cylinder 229, head 7, sector 203
Defect 2 at cylinder 575, head 0, sector 219
Defect 3 at cylinder 576, head 0, sector 55
Defect 4 at cylinder 578, head 0, sector 238
Defect 5 at cylinder 579, head 0, sector 74
Number of GROWN defects on drive: 0

Disk Verify

The disk verify command shows the following types on
information:

Total number and location of primary defects (defects that
originate during manufacturing)

Total number and location of grown defects (defects that
originate after manufacturing)

Displaying Array Information

The CLI allows you to display and manage array attributes using
the following commands:

Container List

Container Show Cache

Container List

The container list attributes are defined as follows:

Drive Letter

—Letter associated with an array. Not

automatically assigned when you create an array.