Nilfisk-ALTO RS 2200 User Manual
Page 171
USER MANUAL
ENGLISH
RS 2200
33019476(3)2010-02 A
49
Problem
Possible cause
Remedy
DRIVE SYSTEM
The machine drive system is disabled
The driver’s seat microswitch is not activated or
it is damaged
Repair/replace
The pedal brake is pressed or stuck
Release the pedal
The power supply fuse is open
Replace
The drive pedal is faulty
Replace
The gear selector is faulty
Replace
The drive system pump solenoid valves are not
powered
Check the electrical system
The drive system pump by-pass screw is
loosen
Tighten
The drive system pump is broken
Replace
The drive system motors are broken
Replace
The machine moves even if the drive pedal is
released
The drive system pump is not properly reset
Adjust
The machine drive power is reduced
The hopper is lifted
Fully lower the hopper and return it to horizon-
tal position
The drive pedal is faulty
Replace
The drive system pump is broken
Replace
The drive system motors are worn
Replace
CAB HEATING
There is no hot air
The valve or the hot water feed hoses are
broken
Replace
There are water leaks from the heater
Replace
The switch is off
Turn on
The main fuse is open
Replace
CAB CLIMATE CONTROL SYSTEM
There is no fresh air
The compressor does not turn because the
drive belt is loosen/broken
Adjust the tension/replace the belt
The thermostat is not turned on
Turn on
There are gas leaks from the system
Repair the leak and integrate the gas
The expansion valve is faulty
Replace
The switch is off
Turn on
The main fuse is open
Replace
There is an open in the gas pressure switch
Replace