Problem

Possible cause

Remedy

SUCTION FAN

The suction fan is noisy

The fan bearings are worn

Replace the motor

The motor is faulty

Replace the motor

The fan is faulty

Repair/replace

The suction fan turns but it is not effi cient

The suction grid are clogged

Clean

The suction hose is clogged

Clean

The suction hose is cut/torn

Replace

The gasket between the suction inlet and the
hopper is broken or misadjusted

Replace/adjust

The hopper is not fully lowered

Fully lower the hopper and return it to horizon-
tal position

The hopper upper panels are opened

Close

There is no pressure at the suction fan motor
drive pump

Adjust the pump pressure

The suction fan turns slowly or does not turn
at all

The working mode is not activated

Activate the working mode switch

The power supply fuse is open

Replace

The distributor solenoid valve is not powered

Check the electrical system

The distributor is stuck

Repair

The motor is faulty

Replace

The pump is faulty

Replace

SUCTION INLET AND SKIRT

The suction inlet does not collect debris ef-
fi ciently

The suction inlet position is not correct

Check the suction inlet and skirt height and
operation

The suction inlet gaskets are worn

Replace

The hopper is not fully lowered

Fully lower the hopper and return it to horizon-
tal position

The suction hose is clogged

Clean

The suction hose is damaged/torn

Replace

The suction inlet does not lift

The working mode is not activated

Activate the working mode switch

The power supply fuse is open

Replace

There is an open in the lifting push-button

Replace

The distributor solenoid valve is not powered

Check the electrical system

The cylinder calibration dowels are clogged

Disassemble and clean

The solenoid valves are stuck

Replace

The cylinder gaskets are worn

Overhaul the cylinders

There is no pressure at the hydraulic system

Check the pump pressure