Brother TD-4100N User Manual
Page 81

[Decimal 1 byte] 104
[Decimal 1 byte] 120
[Decimal 1 byte] 132
[Decimal 1 byte] 144
[Decimal 1 byte] 0
[Decimal 1 byte] 8
[Decimal 1 byte] 12
[Decimal 1 byte] 16
Vertical no. of cells: 104 cells
Vertical no. of cells: 120 cells
Vertical no. of cells: 132 cells
Vertical no. of cells: 144 cells
● ECC200 rectangular
Vertical no. of cells: AUTO
(default value)
Vertical no. of cells: 8 cells
Vertical no. of cells: 12 cells
Vertical no. of cells: 16 cells
4. Horizontal size
[Decimal 1 byte] x
[Decimal 1 byte] 0
[Decimal 1 byte] 18
[Decimal 1 byte] 32
[Decimal 1 byte] 26
[Decimal 1 byte] 36
[Decimal 1 byte] 36
[Decimal 1 byte] 48
● ECC200 square
Horizontal no. of cells: Same value as vertical size (x)
● ECC200 rectangular
1
When the vertical size is “AUTO”
Horizontal no. of cells: AUTO
(default value)
2
When the vertical size is 8 cells
Horizontal no. of cells: 18 cells
Horizontal no. of cells: 32 cells
3
When the vertical size is 12 cells
Horizontal no. of cells: 26 cells
Horizontal no. of cells: 36 cells
4
When the vertical size is 16 cells
Horizontal no. of cells: 36 cells
Horizontal no. of cells: 48 cells
5. Reserved
[Decimal 1 byte]×5 0
5 bytes of dummy data (0) is sent.
*Note:
If the vertical size is set to a value other than those listed for ECC200 square, the “AUTO”
setting is selected. If the horizontal size is set to a value different from the vertical size, the
setting is changed to the same value as the horizontal size.
If the vertical or horizontal size for ECC200 rectangular is set to a value other than those
listed, the “AUTO” setting is selected.
81
②
[Bar code data]: Bar code data
The maximum number of bar code data that can be entered is listed below.
2335 alphanumeric characters, 3116 numbers, 1556 bytes of binary data