beautypg.com

Sterlco SSL and SSIL Series Hopper Loaders User Manual

Page 49

background image

49

Replacement and Reassembly

1. Re-attach the brush clips and the end cap after you make sure that

the brush assembly is properly seated.

Following steps 5 and 6 above, perform the same procedure for
the opposite side.

2. Remove the armature assembly at the top portion of the hopper

loader to properly seat the replacement brushes.

3. Insert a strip of 600-grit sandpaper with the rough side facing the

brush.

4. Release the brush and rotate the commutator back and forth by

hand (See the alternative seating procedure on the facing page) so
that the brush is sanded to match the arc of the commutator.

5. In older motors, the wear of the brushes creates a shallow trough

in the commutator. Sand the brush to conform to the contour.

6. Remove the sandpaper, and repeat steps 5 and 6, as needed until

all brushes are replaced.

7. Reinstall the armature assembly.