Menu 5

Error After n Cycles

0 to 8 Cycles, Default = 3 Cycles

The Error After n Cycles menu lets you:

control the number of unsuccessful loading cycle attempts

(maximum vacuum timer times out and proximity sensor does not
sense a full hopper) before the

Er. 1

error message displays

increase to prevent alarms while you refill the material supply on

high throughput processes

decrease to get earlier warning of material supply problems

disable (

0

)

if you are using a short maximum vacuum time for

less-than-full dumps

Menu 6 External

Activation

Enable/Disable, Default = Disable (0 )

The External Activation menu lets you:

enable or disable recognition of the external system control contact
disable for stand-alone operation
enable if the hopper loader is in a central system and the external

enable contact is in use

Menu 7

Auxiliary Proximity Switch

Enable/Low Bin Op/Ignore, Default = Ignore (0 )

The Auxiliary Proximity Switch menu lets you:

enable a customer-supplied auxiliary proximity switch (

2

)

This proximity switch is typically mounted low in the machine bin
below the hopper loader, and is wired into the hopper loader as
shown in Figure (14). When enabled, if the proximity switch senses
an empty machine bin, the screen displays the

Er. 2

error message

and an optional alarm activates. The hopper loader does not stop.