Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual
Page 64

Page 64
SDAP Series PD 2 to PD 4 Drying and Conveying Systems
Figure 19
Setting List for Dew Point Controller Part No. A0548567 Cont’d.
Mode Parameter
Setting
range
Default
AEC setting
Setup
Cn-t Input Type
0 to 21
2
17
Setup
Cn-H Scaling Upper Limit
Scaling Lower Limit +1 to
9999 EU
-100
15
°F/-9C
Setup
Cn-L Scaling Lower Limit
-1999 to SP Setting Upper
Limit –0.1 EU
0
-40
°F/-40C
Setup
dP Decimal Point
0 to 3
0
Default
Setup
CnCE Parameter Initialize
Yes/No
No
Default
Setup
6Ut1 Control Output 1
Assignment
Heat/Cool/Alarm 1/Alarm 2/
Alarm 3/LBA
Heat COOL
Setup
6Ut2 Control Output 2
Assignment
Heat/Cool/Alarm 1/Alarm 2/
Alarm 3/LBA
AL-1 Default
SetUp
Sub 1 Auxiliary Output 1
Assignment
Alarm 1/Alm 2/Alm 3/LBA/S.
ERR/E333
AL-2 Default
Setup
ALt1 Alarm 1 Type
0 to 11
2
8
Setup
AL1n Alarm 1 open in alarm
NO/NC
NO
Default
Setup
ALt2 Alarm 2 Type
0 to 11
2
8
Setup
AL2n Alarm 2 open in alarm
NO/NC
NO
Default
Setup
6rEU Direct/Reverse
Operation
OR-R/OR-D OR-R
Default
Expansion SL-H Set Point Upper Limit
SP Lower Limit +1 to
Scaling Upper Limit
1300
15
°F/-9C
Expansion SL-L Set Point Lower Limit
Scaling Upper Limit to Sp
Lower Limit
-200
-40
°F/-40C
Expansion CntL PID/ON/OFF
PID/ON-OFF
PID
ON-OFF
Expansion
rESt Standby Sequence
Reset Setting Method
0/1 0
Default
Expansion
rEt Automatic Return of
Display Mode
0 to 99 SEC
0
Default