Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual
Page 59

SDAP Series PD 2 to PD 4 Drying and Conveying Systems
Page 59
Entering Operating Parameters to Select Modes
To enter the menu display:
1. Press
for one second (keep the pressure on the button for about 1.5 to 2 seconds).
The screen displays
.
2. Press the
Up Arrow key to toggle through the different modes.
The
SV
readout displays the mode you selected.
3. To switch parameters within a mode, press the
Display key once more for about
one and a half to two (1.5 to 2) seconds.
The
PV
readout displays the different parameters within each mode.
4. Use short presses on the
Display key to display each parameter within a mode.
The
SV
readout displays the different values for the parameter within a mode.
5. Press
and
to set the higher or lower the values of a parameter.
6. Press
for about one and a half to two (1.5 to 2) seconds to move up a level back
into the different modes.
7. Press
until Level 0 displays.
8. Press
for about one to one and a half (1 to 1.5) seconds to go to Operating mode.
Factory Settings E5CK for Process Temperature
1. Remove controller from housing and check for output board number E53-QR4R (Pulse
NPN/Relay).
2. Make sure jumper setting for input type is set for thermocouple
TC-PT
, middle jumper.
3. Return controller to housing.
4. Press the
Display key for one (1) second to enter Menu Display.
5. Press the
Arrow Up key to get to Setup mode.
6. To switch parameters within Setup mode, press the
Display key.