SDAP Series PD 2 to PD 4 Drying and Conveying Systems
Page 29
4 Controls
4-1 Control Panel Indicator Lights and Switches
Rocker Switches
System ON/OFF Rocker Switch
Press the
ON/OFF
rocker switch energizes or de-energizes control power to the indicator panel,
allowing separate control of the dryer and conveying systems.
Dryer ON/Sequence Shutdown Rocker Switch
Press the
ON/Sequence Shutdown
rocker switch to start the dryer. Move this switch to the
Sequence Shutdown position to turn off the process heaters, finish the regeneration cycle and
then turn off the dryer.
Machine Loading ON/OFF Rocker Switch
Press the
ON/OFF
rocker switch to start or stop the machine loader conveying system.
Optional Drying Hopper Loader ON/OFF Rocker Switch
Press the
ON/OFF
rocker switch to start or stop the Drying Hopper loader conveying system.
Optional Alarm Silence Rocker Switch
Press the
Alarm Silence
switch to silence the horn when a high temperature alarm activates. The
alarm repeats every five minutes until the problem causing the alarm condition is cleared.
Indicating Lights
Regen Blower On Light
The
Regen Blower On
indicator lights when the regeneration blower energizes.
Left Bed In Regen Light
The
Left Bed In Regen
LED lights when the left bed is in regeneration.
Left Bed Heater Light
The
Left Bed Heater
indicator lights when the left bed regenerates and is in the heat-up portion
of the regeneration cycle.