E5ck factory setting for dew point – Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual
Page 63

SDAP Series PD 2 to PD 4 Drying and Conveying Systems
Page 63
E5CK Factory Setting for Dew Point
1. Make sure jumper setting for input type is set for Current Input (I), right jumper.
2. Return controller to housing.
3. Press the
Display Key for one (1) second to enter Menu Display.
4. Press the
Arrow Up to switch between menus.
5. To switch parameters within a menu, press
Arrow Up.
Figure 19
Setting List for Dew Point Controller, Part No. A0548567
Mode Parameter
Setting
range
Default
AEC setting
Protect SECr Security
0 to 6
1
3
Protect YEYP A/M Key Protect
ON/OFF
OFF
ON
Manual Manual MV
-5.0 to 105.0 %
0.0
Default
Level 0 SP Set Point
SP lower limit to upper limit EU
0
Default
Level 0 r-S Run/Stop
Run/Stop
Run
Default
Level 1 AL-1 Alarm Value 1
-1999 to 9999 EU
0
-10.0
°F/-23°C
Level 1 AL-2 Alarm Value 2
-1999 to 9999 EU
0
-10.0
°F/-23°C
Level 1 C-db Dead Band
-19.99 to 99.99%FS
0.00
Default
Level 1 HYS Hysteresis (Heat)
0.01 to 99.99% FS
0.10
Default
Level 1 CHYS Hysteresis (Cool)
0.01 to 99.99 FS
0.10
Default
Level 2 SPrU Sp Ramp Time Unit
M(Minutes)/H(Hours)
M
Default
Level 2 SPrt Sp Ramp Set Value
0 to 9999 EU
0
Default
Level 2 CnF Input Digital Filter
0 to 9999 SEC
0
Default
Level 2 ALH1 Alarm 1 Hysteresis
0.01 to 99.99%
0.02
Default
Level 2 ALH2 Alarm 2 Hysteresis
0.01 to 99.99%
0.02
Default
Level 2 Cn5H input shift upper limit
-199.9 to 999.9
°C
0.0 Default
Level 2 Cn5L input shift lower limit
-999.9 to 999.9
°C
0.0 Default