Sterlco SDAP 90-225 CFM Series Drying and Conveying Systems User Manual
Page 40

Page 40
SDAP Series PD 2 to PD 4 Drying and Conveying Systems
Alarm Horn Output (O/7)
Optional
The
Alarm Horn Strobe Output
indicates a high process temperature condition and optional
critical low level at the drying hopper.
Machine Loader Convey Blower (O/8)
When
ON
, the
Machine Loader
convey blower contactor is energized.
Drying Hopper Convey Blower (O/9)
Optional
When
ON
, the
Drying Hopper
convey blower contactor is energized.
Machine Loader Convey Timer (O/10)
When
ON,
the convey timer starts timing a loading process.
Drying Hopper Convey Timer (O/11)
Optional
When
ON,
the convey timer starts timing a loading process.
Status LED Indicators
Power
The
Power
indicator lights when the PLC receives 115V control power.
Run
The
Run
indicator lights when the PLC executes the program in normal conditions.
Fault
The
Fault
indicator lights when the PLC program has a problem or failure condition.
Force
The
Force
indicator is not used.