beautypg.com

Table 2-3: operating conditions, Parameter symbol min typ max units – PNI SENtral MandM User Manual

Page 8

background image

PNI Sensor Corporation

Doc #1020129 revE

SENtral M&M Technical Datasheet

Page 7

Table 2-3: Operating Conditions

Parameter

Symbol

Min

Typ

Max

Units

Digital Supply Voltage

– Sensors &

EEPROM

DVDD

1.71

AVDD

VDC

Supply Voltage

– SENtral

DVDD2

1.6

3.3

VDC

Analog Supply Voltage

– Sensors

AVDD

2.4

3.6

VDC

Power-On Reset Threshold

V

POR

1.0

VDC

High Level Input Voltage

V

IH

0.7*V

DD

V

DD

VDC

Low Level Input Voltage

V

IL

0

0.3*V

DD

VDC

High Level Output Current, V

OH

= V

DD

– 0.3V

I

OH

-1

mA

Low Level Output Current, V

OL

= 0.3V

I

OL

1

mA

I

2

C Interface

Data Rate

1

Host Bus

3400

kbits/sec

Sensor Bus

1000

kbits/sec

Pass-Through

400

kbits/sec

Operating Temperature

T

OP

-40

+25

+85

C

Footnote:

1.

SENtral’s I

2

C Host Interface supports Standard, Fast, Fast Plus, and High Speed Modes.

High Speed Mode (3400 kHz) is supported with a reduced range of V

DD

and bus

capacitance. SENtral’s I

2

C sensor bus interface supports Standard, Fast, and Fast Plus

Modes. Pass-Through state, which connects the sensor bus and host bus, supports
Standard and Fast Modes.