Table 2-3: operating conditions, Parameter symbol min typ max units – PNI SENtral MandM User Manual
Page 8

PNI Sensor Corporation
Doc #1020129 revE
SENtral M&M Technical Datasheet
Page 7
Table 2-3: Operating Conditions
Parameter
Symbol
Min
Typ
Max
Units
Digital Supply Voltage
– Sensors &
EEPROM
DVDD
1.71
AVDD
VDC
Supply Voltage
– SENtral
DVDD2
1.6
3.3
VDC
Analog Supply Voltage
– Sensors
AVDD
2.4
3.6
VDC
Power-On Reset Threshold
V
POR
1.0
VDC
High Level Input Voltage
V
IH
0.7*V
DD
V
DD
VDC
Low Level Input Voltage
V
IL
0
0.3*V
DD
VDC
High Level Output Current, V
OH
= V
DD
– 0.3V
I
OH
-1
mA
Low Level Output Current, V
OL
= 0.3V
I
OL
1
mA
I
2
C Interface
Data Rate
1
Host Bus
3400
kbits/sec
Sensor Bus
1000
kbits/sec
Pass-Through
400
kbits/sec
Operating Temperature
T
OP
-40
+25
+85
C
Footnote:
1.
SENtral’s I
2
C Host Interface supports Standard, Fast, Fast Plus, and High Speed Modes.
High Speed Mode (3400 kHz) is supported with a reduced range of V
DD
and bus
capacitance. SENtral’s I
2
C sensor bus interface supports Standard, Fast, and Fast Plus
Modes. Pass-Through state, which connects the sensor bus and host bus, supports
Standard and Fast Modes.