beautypg.com

NORD Drivesystems B2050 User Manual

Page 9

background image

3. Assembly instruction,

storage, transport, preparation, installation

www.nord.com B2050-GB-0613

-9-

Measures before commissioning
 If the storage or standstill period exceeds 2 years or the temperature during short-term

storage greatly deviates from the standard range, the lubricant in the gear unit must be
replaced before commissioning.

If the gear unit is completely filled, the oil level must be reduced before commissioning.

3.3 Inspecting the drive unit

Danger!

The drive unit must be inspected and may only be installed if:

No damage, e.g. due to storage or transport is apparent. In particular the shaft

sealing rings, the sealing caps and the covers must be inspected for damage.

No leakage or no oil loss is visible.
No corrosion or other indications of incorrect or damp storage is apparent.
The packaging material has been completely removed.

3.4 Checking the name plate data

The name plate must be firmly attached to the gear unit and must not be subjected to permanent
soiling. Please contact the NORD service department if the name plate is illegible or damaged.

Figure 3-1: Name Plate (example)