Appendix – NORD Drivesystems B2050 User Manual
Page 41
6. Appendix
www.nord.com B2050-GB-0613
-41-
6.2 Lubricant quantities
Note!
After changing the lubricant, and in particular after the initial filling, the oil level may
change during the first few hours of operation, as the oil galleries and hollow spaces
only fill gradually during operation.
The stated filling quantities are for guidance only. The precise quantities vary
depending on the exact gear ratio.
If at the express request of the customer, an oil inspection glass is installed at an
additional charge, we recommend that the customer corrects the oil level after an
operating period of approx. 2 hours, so that when the gear unit is at a standstill and has
cooled down, the oil level is visible in the inspection glass. Only then, is it possible to
check the oil level by means of the inspection glass.
Danger!
When filling, always observe the oil level screw as an indicator of the precise quantity
of oil. After filling, the oil level must be checked as described in Section 4.1.
Helical gear unit
[L]
M1
M2
M3
M4
M5
M6
Max.
SK 11207
105
130 ( 50 )
105
140 ( 40 )
135 ( 45 )
135 ( 45 )
180
SK 11307
105
130 ( 50 )
105
140 ( 40 )
135 ( 45 )
135 ( 45 )
180
SK 12207
116
185 ( 83 )
116
203 ( 65 )
199 ( 69 )
199 ( 69 )
268
SK 12307
116
185 ( 83 )
116
203 ( 65 )
199 ( 69 )
199 ( 69 )
268
SK 13207
154
256 ( 107 )
154
290 ( 73 )
268 ( 95 )
268 ( 95 )
363
SK 13307
154
256 ( 107 )
154
290 ( 73 )
268 ( 95 )
268 ( 95 )
363
SK 15207
358
415 ( 160 )
335
450 ( 125 )
405 ( 170 )
412 ( 163 )
575
SK 15307
358
415 ( 160 )
335
450 ( 125 )
405 ( 170 )
412 ( 163 )
575