3. Storage, preparation,

installation

www.nord.com B2000-GB-0413

-13-

Measures before commissioning

 If the storage or standstill period exceeds 2 years or the temperature during short-term

storage greatly deviates from the standard range, the lubricant in the gear unit must be
replaced before commissioning (See Section 5.2).

 If the gear unit is completely filled, the oil level must be reduced before commissioning (See

Section 3.5 and 6.1).

3.3 Inspecting the drive unit

Danger!

The drive unit must be inspected and may only be installed if:
No damage, e.g. due to storage or transport is apparent. In particular the shaft

sealing rings, the sealing caps and the covers must be inspected for damage.

No leakage or no oil loss is visible.
No corrosion or other indications of incorrect or damp storage is apparent.
The packaging material has been completely removed.

3.4 Checking the rating plate data

The rating plate must be firmly attached to the gear unit and must not be subjected to permanent
soiling. Please contact the NORD service department if the rating plate is illegible or damaged.

Figure 3-1: Rating plate (example)