Programming
All settings made in programming mode will be maintained in memory even if the batteries are removed. The
following features of the system can be programmed.

a. Control panel button function and Battery Fault Monitor
The control panel button is located at the centre of the LED diamond. There are three possible options for this
button. It can be used as either a SILENCE button, a RESET button or be completely disabled. There are also two
possibilities for the Battery Fault Monitor (BFM) on or off, ie six combinations altogether.
The default setting is probably adequate for most applications but if it needs to be changed proceed as follows:
Move the jumper on the PCB to the Set position. The LEDs will flash indicating the current setting (Silence & BFM
for factory default ie Set 1 in the table opposite.) Scroll through the possibilities by pressing the small Set Button
on the reverse of the PCB. When finished either continue to set the tone as in (b) below, or move the Set mode
jumper back to the Use mode.
We do not recommend that you turn the Battery Fault Monitor off on this version of the product as its only
power source is the batteries.

b. Control panel alarm tone
Whilst in Set mode (jumper on the PCB in the Set position), press the control panel button in the centre of the LED
diamond to move into tone setting mode, the LED will indicate steady. Repeatedly press the control panel button
to scroll through the four different tones. Pause for 2 seconds after each press and the selected tone will play for 2
seconds. The last tone played is the tone that will be stored in memory. When finished, move the Set mode
jumper back to the Use mode.

AIDALARMs and accessories are supplied as individual items or in kit form. Kit part numbers are:

A600LKITM (A600L AIDALARM controller, S1600 pull cord, S1708A reset button and S1778A
overdoor light/buzzer)

A600LKITMD (A600L AIDALARM controller, S1600 pull cord, S1708A reset button, S1778A overdoor light/buzzer and RPD01000 1m
length of DADO Panic strip)

A600LKITB (A600B (Battery powered) AIDALARM controller, S1600 pull cord, S1708A reset button and S1778A overdoor light/buzzer)

aidalarm

Control Panel Button

Battery

Monitor

LED

Display

Set

1

2

3

4

5

6

Function

Button

ON

ON

ON

OFF

OFF

OFF

SILENCE

SILENCE

RESET

RESET

DISABLE

DISABLE

1 is the factory default setting

60139 Iss 1 Sept 2011

T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com

Hoyles Electronic Developments Ltd

Also available from Hoyles...

Mains Powered Toilet Alarm Kit - A600LKITM

6 Zone Toilet Alarm System - AA31110D

Mains powered
Battery backup
BS8300 and DDA compliant

6 zone control panel providing central indication of calls.
Expandable
Repeater panels available
Requires 1 x pull cord (S1600), 1 x over door light / sounder S1778A
and 1 x reset button S1708A per zone (Available separately).
BS8300 and DDA compliant

S1600

S1778A

S1778A

This manual is related to the following products: