Dimensions, A b c d, Redimon – Hoyles Redimon v3 Monitor User Manual
Page 2: Hoyles electronic developments ltd, Panic strip

In M ode 2 operation a 10K End of Line resistor is fitted at the remote
end of each length of
. Pressing either
twice, within a 5 second window will be seen as an alarm condition.
This double action reduces the number of false alarms caused by
accidental pressing. If the
becomes disconnected in any
way, or is held pressed for longer than 5 seconds, a fault condition is
generated. The Redimon requires 12 volts dc and provides volt free
changeover contacts for both alarm and fault. A reset button is
provided.
eg. Footswitch or
pushbutton.
Panic Strip
Panic Strip
Panic Strip
Redimon can also be used to create a double pole EOL circuit
for any
momentary action normally open device.
Redimon is supplied with two 6k8 end of line resistors fitted to the
terminals AB and CD for Mode 1 operation and test purposes.
These resistors should be replaced with ones of 10K value for
Mode 2 operation. If only one length of
is being
monitored one of these resistors should be left in either AB or CD
terminals and the other terminals used for the
.
Panic Strip
Panic Strip
Any other type of non-latching open circuit button or switch could
be wired across
Panic Strip
circuits to complement the system
as in
Panic Strip
2 shown below.
Under normal circumstances the GREEN LED will be illuminated to show that power is on and the circuits are healthy. When
either Panic Strip is operated the RED LED will illuminate and the alarm relay will change over. If either of the Panic Strip
circuits becomes disconnected the RED and GREEN LEDs will alternate and the fault relay will operate, this will restore when
the circuit has been repaired. To reset the Panic Strip from an alarm condition press the Reset button.
Dimensions in mm
Dimensions
R
12 Volts dc power
45ma max
Alarm output
Fault output
Panic Strip Type 3
Panic Strip Type 3
Use these changeover contacts to connect to the personal attack circuit of your intruder alarm.
Use these changeover contacts to connect to the tamper circuit of your alarm
11 - 14 volts dc at all times. Quiescent current 30ma Max current 45ma
E.O.L 10K
E.O.L 10K
ALARM
OUTPUT
FAULT
OUTPUT
TAMPER
OUTPUT
T1
T2
10K Terminating resistors
Panic Strip
Type 2
Panic Strip
Type 3
Panic Strip
Type 3
Panic Strip
Type 2
These contacts are rated @ 30vdc 1A
Optional open circuit
non-latching push button
A B C D
NOTE
Panic Strip
SHOULD NEVER BE
CONNECTED DIRECTLY TO MAINS
VOLTAGE CIRCUITS.
IT IS ONLY RATED FOR SAFE WORKING
ON 43 VOLTS MAXIMUM.
T1 and T2 are normally closed. Opening this circuit will cause a fault
until the circuit is closed again. If wired as shown, removing the unit
cover will cause a fault to be indicated, until the cover is replaced.
T. 01744 886600 F. 01744 886607 E. [email protected] W. www.hoyles.com
Hoyles Electronic Developments Ltd
Dwg No: 60136 Oct 2011
Mode 2 operation - Double push
Latching monitor unit for Panic Strip
v3
Redimon
87.0
18.0
18.0
8
7
.0
v3
Redimon Monitor
Press to Reset
v3
Redimon Monitor
Press to Reset
NO
NO
COM
RELAY 1
RELAY 2
COM
NC
NC
TAMPER
SWITCH