E. specifications – Dwyer TFM-LP User Manual
Page 21

F-20-TF-L, pg. 21 of 30
E.
Specifications
Model TFP-LP
Model TFM-LP
Analog Signal Accuracy
(including linearity)
±1.0% Full Scale
1
Repeatability
±0.2% Full Scale
1
Pressure Rating
100 psig
(6.8 bar)
500 psig
(34.5 bar)
Temperature Rating
Operating Range: 5 to 55°C
Storage Range: 0 to 70°C
Temperature Sensitivity
±0.2% F.S.
1
or less per °C
Wetted Materials
Ryton
®
Epoxy
Glass
Sapphire
316 Stainless
Ryton
®
Epoxy
Glass
Sapphire
O-Ring Material
Viton
®
Fitting Material (Standard)
Acetal
Stainless Steel
Fitting Material Optional
Kynar PVDF
Brass
Stainless Steel
Acetal
Kynar PVDF
Brass
Recommended Filtration
25 microns or less
Compatible Liquids
Low viscosity (ideally <10cS)
Translucent or transparent
Minimum amount of entrapped air or gas
0-5VDC Output Signal
Standard
Minimum 2.5 K
Ω load
Pulse Output Signal
7.5VDC peak buffered square wave
Typically 0-400Hz
±3.0% Full Scale accuracy
Typical Power Consumption
12 VDC @ 35 mA
(11.5-15 VDC)
Response Time
Typically <1 second for 63% of final value
Reliability
100,000 hours MTBF
Certifications CE
Approved
89/336/EEC
(EN 55011 & EN 50082-1)
73/23/EEC Low Voltage Directive
Ratings
IP10 (NEMA 1)
Warranty
1 year limited
1. Specifications from 10-100% of rated flow. Linearity is best fit straight line. All calibrations performed
with deionized water unless otherwise stated on calibration certificate