E.

Specifications

Model TFP-LP

Model TFM-LP

Analog Signal Accuracy
(including linearity)

±1.0% Full Scale

1

Repeatability

±0.2% Full Scale

1

Pressure Rating

100 psig
(6.8 bar)

500 psig

(34.5 bar)

Temperature Rating

Operating Range: 5 to 55°C

Storage Range: 0 to 70°C

Temperature Sensitivity

±0.2% F.S.

1

or less per °C

Wetted Materials

Ryton

®

Epoxy

Glass

Sapphire

316 Stainless

Ryton

®

Epoxy

Glass

Sapphire

O-Ring Material

Viton

®

Fitting Material (Standard)

Acetal

Stainless Steel

Fitting Material Optional

Kynar PVDF

Brass

Stainless Steel

Acetal

Kynar PVDF

Brass

Recommended Filtration

25 microns or less

Compatible Liquids

Low viscosity (ideally <10cS)

Translucent or transparent

Minimum amount of entrapped air or gas

0-5VDC Output Signal

Standard

Minimum 2.5 K

Ω load

Pulse Output Signal

7.5VDC peak buffered square wave

Typically 0-400Hz

±3.0% Full Scale accuracy

Typical Power Consumption

12 VDC @ 35 mA

(11.5-15 VDC)

Response Time

Typically <1 second for 63% of final value

Reliability

100,000 hours MTBF

Certifications CE

Approved

89/336/EEC

(EN 55011 & EN 50082-1)

73/23/EEC Low Voltage Directive

Ratings

IP10 (NEMA 1)

Warranty

1 year limited

1. Specifications from 10-100% of rated flow. Linearity is best fit straight line. All calibrations performed
with deionized water unless otherwise stated on calibration certificate