Part number construction, Part number construction 9 – Badger Meter B3000 User Manual
Page 9

Programming Manual
Page 9
March 2014
Response Time (Damping)
Common Response
Time
1…100 seconds response to a step change input, user adjustable
Environmental Limits
Common Limits
–22…158° F (–30…70° C); 0…90% humidity, non-condensing;
Materials and Enclosure Ratings
B30A/B/L/M/S
Polycarbonate, stainless steel, polyurethane, thermoplastic elastomer, acrylic; NEMA 4X/IP 66
B30W/X/Y/Z
Copper free, epoxy-coated, aluminum, buna seal, NEMA 4X/IP66
Engineering Units
Liquid
Gallons, Liters, Oil Barrels (42 gallon), Liquid Barrels (31 5 gallon), Cubic Meters, Million Gallons,
Cubic Feet, Million Liters, Acre Feet
Gas
Cubic Feet, Thousand Cubic Feet, Million Cubic Feet, Standard Cubic Feet, Actual Cubic Feet, Normal
Cubic Meters, Actual Cubic Meters, Liters
Rate Time
Seconds, minutes, hours, days
Totalizer Exponents 0 00, 0 0, X1, x10, x100, x1000
K factor Units
Pulses/Gallon, Pulse/cubic meter, pulses/liter, pulses/cubic foot
PART NUMBER CONSTRUCTION
Blancett B3000 Display
-
Model
Blancett B3000 Display
B30
Model
Base
B
Advanced
A
Solar
S
Base – Loop Powered Only
L
Base – Explosion Proof*– Loop Power Only
W
Base – Explosion Proof* – Battery & Loop Power
X
Advanced – Loop Powered Only
M
Advanced – Explosion Proof* – Loop Power Only
Y
Advanced – Explosion Proof* – Battery & Loop Power
Z
Mounting
Meter
M
Remote
R
Swivel
S
Units of Measure
Customer Selectable
CS
*For hazardous locations the monitor must be installed on an Explosion-Proof rated meter To
maintain compliance, optional kit P/N B280-737 for meter mounting is required