beautypg.com

Technical data 43, Technical data, Out3 as universal output – West Control Solutions D280-1 User Manual

Page 43: Functions, Alarm + maintenance manager, Display, Power supply, Ac supply, Universal supply 24 v uc, Behaviour with power failure

background image

OUT3 AS UNIVERSAL OUTPUT

Galvanically isolated from the inputs.

Freely scalable
Resolution:

11 Bit

Timeconstant of DA-transducer T90

50 ms

Limitfrequency of the whole continuous
controller

> 2 Hz

Current output

0/4...20 mA configurable.
Signal range:

0...ca.21,5 mA

Max. load:

£ 500 W

Load effect:

0,02 % / 100

W

Resolution:

£ 22 mA (0,1%)

Accuracy

£ 40 mA (0,2%)

Voltage output (short-circuit proof)

0/2...10V configurable
Signal range:

0...ca.11 V

Min. load:

³ 2 kW

Load effect:

kein Einfluß

Resolution:

£ 11 mV (0,1%)

Accuracy

£ 20 mV (0,2%)

OUT3 used as transmitter supply

Output power:

22 mA /

³ 13 V

OUT3 used as logic output

Load

£ 500 W

0/

£ 20 mA

Load > 500

W

0/> 13 V

FUNCTIONS

Control behaviour

w

Signaller with adjustable siwtching
difference (ON/OFF controller)

w

PID controller (2-point and continuous)

Control parameters self-adjusting or manually adjustable via
front panel keys or BlueControl software.

Limit value functions

Monitoring is provided for: exceeded max., min. or max. and
min. limit value with adjustable hysteresis.

The following signals can be monitored:

w

Measured value

w

Process value

w

Control deviation

w

Control deviation with suppression after
start-up or set-point changes

w

Set-point

w

Correcting variable Y

Functions

w

Measured value monitoring

w

Measured value monitoring with storage.
Reset via front panel keys or digital input

w

Measured value change

w

Measured value change and storage

Several limit values and alarms can be combined by a logic OR
function and output e.g. as a common alarm.

ALARM + MAINTENANCE MANAGER

Displayof error messages, warnings and stored limit signallings
in the error list.
Messages are stored and can be reset manually.

Possible elements of the error list:

w

Sensor break, short circuit, polarity error

w

Self-tuning error

w

Stored limit values

-

E.g. recalibration warning
(when exceeding an adjustable number of

operating hours, a message is displayed)

-

E.g. maintenance interval of switching element

(when exceeding an adjustable number of
switching cycles, a message is displayed)

w

Internal errors (RAM, EEPROM, ...)

DISPLAY

Display

5-digit 19 mm LED

POWER SUPPLY

Dependent of order:

AC SUPPLY

Voltage:

90...250 V AC

Frequency:

48...62 Hz

Power consumption

approx. 7.3 VA

UNIVERSAL SUPPLY 24 V UC

AC voltage:

20,4...26,4 V AC

Frequency:

48...62 Hz

DC voltage:

18...31 V DC

Power consumption:

approx.. 7.3 VA

BEHAVIOUR WITH POWER FAILURE

Configuration, parameters and adjusted

set-points, control mode:
Non-volatile storage in EEPROM

BLUEPORT FRONT INTERFACE

Connection of PC via PC adapter (see "Accessory equipment").
The BlueControl software is used to configure, set parameters
and operate the KS4x-1.

BUS INTERFACE (OPTION)

Galvanically isolated
Physical:

RS 422/485

Technical data

Digital 280-1

43