beautypg.com

SHIMPO DT-5TS User Manual

Page 8

background image

8

Mode -01- (RPM or Rate Measurement) continued

Set the parameters in mode -01- as follows:
1. Press the PAR button; the display will indicate:

The “-01- P01” on secondary display A indicates that

the meter is in the RPM mode (-01-) and parameter 1

is showing on the primary display (1 ppr [factory

setting]).

2. Using the NUMERIC buttons, enter the number of

pulses per revolution produced by the sensor being

used (1-9999). For example, if a rotary pulse

generator has an output of 60 ppr, then 6 0 would

have to be entered.

3. Press the PAR button; the display will reflect:

The secondary display A reflects that the meter is

still in mode -01-, but parameter 2 is showing on the

primary display (1000 RPM [factory setting]).

4. Using the NUMERIC buttons, enter the number of

RPM that must be monitored (up to 99999). For

example, if the motor to be monitored has a speed

of 1,750 RPM, then 1 7 5 0 would have to be entered.

5. Press the PAR button; the display will show:

As the secondary display indicates, parameter 3 is

reflected on the primary display (1000 [factory

setting]).

6. Use the NUMERIC buttons to enter the value of the

display as it relates to the already programmed RPM

setting. For example: if the desired display reading

is feet per minute and the belt that is being measured

is moving at a rate of 55.5 f/min, then 5 5 5 would

have to be entered and the negative/decimal point

button pressed once. If the desired reading is RPM,

then the same 1 7 5 0 would have to be entered.

7. Press the PAR button; the display will reflect:

Parameter 4 is now showing on the primary display

(1.0 second [factory setting]).

8. Use any of the lower buttons to scroll through the

update times (see table under “Setting Mode

Parameters” on page 7) until the desired reading is

displayed.

9. Press the PAR button, the display will indicate:

The primary display is now reflecting parameter 5

(6 sec [factory setting]).

10. Press the NUMERIC buttons to enter the value in

seconds that the display should hold the final reading

after the input signal ceases.

11. Press the PAR button; the display will reflect:

Parameter 6 is showing on the primary display (10

kHz [factory setting]).

12. Refer to the “Connection of Sensors” chart under

the “Set-Up” section for the proper filter for the

sensor being used. Press any of the lower buttons

to scroll through the input filters (see table under

“Setting Mode Parameters” on page 7) until the

desired reading is showing.

13. Press the SET button to store the parameter settings

and exit.

NOTE: Please see page 13 for an example of MODE -01-

operation.

This manual is related to the following products: