beautypg.com

SHIMPO DT-5TS User Manual

Page 12

background image

12

Setting Functions (continued)

Instructions to set functions are as follows:
1. Press the FUN button; the display will indicate:

NOTE: The display will always show what operating

mode is set (mode -01- in this example) and what

function (1) is being displayed.

2. Use the lower keys to set secondary high and low

limits (follow the same instructions listed under

“Setting High and Low Limits” section on page 7).

3. Press the FUN button; the display will reflect:

Function 2 is now showing on the primary display

(factory setting).

4. Use the NUMERIC buttons to set the hysteresis of

the upper and lower limits.

5. Press the FUN button; the display will show:

Function 3 is being reflected on the primary display

(factory setting).

6. Use any of the lower buttons to toggle between

securing and not securing (see tables on page 11)

the primary high and low settings.

7. Press the FUN button; the display will reflect:

Function 4 is now showing (factory setting).
NOTE: This function is mainly used with mode -01-

only.

8. Use the NUMERIC buttons to set the output activation

of any set limit.

9. Press the FUN button, the display will show:

Function 5 is now showing (factory setting).

Memory Feature

The function of the MEM button is to aid the

DT-5TXR/DT-5TS to memorize and display through the

secondary displays the maximum and minimum value of

the main display for as long as it has been activated.

Simply activate the MEM button by pushing it

momentarily. The lower left secondary display will reflect

the maximum value of the main display and the lower

right secondary display will reflect the minimum value of

the main display. Also a small LED will begin to flash.

To de-activate the memory feature, simply push the MEM

button again. The LED under it will stop flashing and

the secondary displays will return to their previous state.

10. Use any of the lower buttons to toggle between

the three settings (see tables on page 11) for what

the secondary displays (A and B) will show.

11. Press the FUN button; the display will reflect:

Function 6 is now showing (factory setting).

12. Use the NUMERIC buttons to enter the number at

which the primary display should read zero.
For example: if it is desired for the display to read

zero when the RPM drops below 600, then 6 0 0

should be entered.

13. Press the FUN button; the display will show:

Parameter 7 is now showing (factory setting).

14. Use any of the lower buttons to scroll between the

three types of averaging (see tables on page 11) for

an unstable sensor. The number of times that the

meter will average the frequency is directly related

to the update time chosen (parameter 4).

15. Press the FUN button; the display will reflect:

Parameter 8 is now showing (factory setting).

16. Use the lower keys to toggle between either having

the deceleration to zero value “on” or “off” (see tables

on page 11).

17. Press the SET button to store the function settings

and exit.