SHIMPO DT-329 User Manual
Page 24

21
Operation
Expression
4.5.2
Trigger
Edge setting (External Mode)
Select Positive or Negative edge.
Examples:
-When trigger edge setting is set to “Positive Edge”, the flash will occur on the positive edge of the input
pulse (when delay setting is zero).
-When the trigger edge setting is set to “Negative Edge”, the flash will occur on the negative edge of the
input pulse (when delay setting is zero).
External Pulse signal
from machine/sensor
Stroboscope flash
*Delay time (based on the delay settings of parameter)
*
*
*
Stroboscope flashing
:*Delay time (based on the delay settings of parameter)
*
*
*
External Pulse signal
from machine/sensor
Measuring range set to
“1 – 200 Hz”
Or
Or
FLASH
PHASE+
Press and release
Turn clockwise
Measuring range set to
“1 – 2000 Hz”
Measuring range set to
“1 – 200 Hz”
Measuring range set to
“1 – 2000 Hz”
Turn counter
clockwise
FLASH
PHASE+
FLASH
PHASE-
FLASH
PHASE-
Press and release
Auto
Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min
Max
min
sec
h
Hz
○○○○
ms
Auto
Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min
Max
min
sec
h
Hz
○○○○
ms
Auto
Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min
Max
min
sec
h
Hz
○○○○
ms
Auto
Range
Trigger
Edge Deley Deg
Flash Time
Ave Last Min
Max
min
sec
h
Hz
○○○○
ms