4.4.2.1 “Delay time” setting

This can be set to 0~999 msec with a resolution of 1 ms.

The internal calculation time of the unit is 60us, which results in the actual delay time being (Setting delay

time) + 60us.

The DT-329 will begin flashing after the 1

st

trigger pulse. See timing chart below.

[Example]

Trigger: Positive edge (The instant where the delay time)

Delay time: 10ms (Independent of external input frequency)

If external signal period < delay time, then the delay time value = 0.

Please note the built in 60us internal delay on top of the external signal input.

External Pulse
Input

LED Flash

100ms

10ms

Delay

80ms

10ms

Delay

Measure

frequency

Measure

frequency