SHIMPO DT-329 User Manual
Page 18

15
4.4.2.1 “Delay time” setting
This can be set to 0~999 msec with a resolution of 1 ms.
The internal calculation time of the unit is 60us, which results in the actual delay time being (Setting delay
time) + 60us.
The DT-329 will begin flashing after the 1
st
trigger pulse. See timing chart below.
[Example]
Trigger: Positive edge (The instant where the delay time)
Delay time: 10ms (Independent of external input frequency)
If external signal period < delay time, then the delay time value = 0.
Please note the built in 60us internal delay on top of the external signal input.
External Pulse
Input
LED Flash
100ms
10ms
Delay
80ms
10ms
Delay
Measure
frequency
Measure
frequency
See also other documents in the category SHIMPO Tools:
- DT-361 (36 pages)
- DT-365E (28 pages)
- DT-311A (4 pages)
- DT-311J (12 pages)
- DT-315AEB (4 pages)
- DT-315P (17 pages)
- DT-326 (35 pages)
- DT-725 (4 pages)
- DT-900 (33 pages)
- ST-1000 (2 pages)
- ST-5000 (4 pages)
- SG-300 (2 pages)
- DT-721 (4 pages)
- DT-105A (2 pages)
- DT-107A (2 pages)
- MT-100 (4 pages)
- MT-200 (4 pages)
- PT-110 (2 pages)
- DT-105A-S12 (2 pages)
- DT-205L (4 pages)
- DT-205L-S12 (4 pages)
- DT-207L (4 pages)
- DT-207L-S12 (4 pages)
- DT-209X (68 pages)
- DT-5TXR (20 pages)
- DT-5RL-1 (2 pages)
- DT-5TP (8 pages)
- DT-601CG (54 pages)
- FGV-XY-Series (32 pages)
- FGE-X (8 pages)
- FGE-HX (8 pages)
- FG-3000 (8 pages)
- FG-7000-Series (8 pages)
- DFS-series (20 pages)
- DRI-series (20 pages)
- EM-series (2 pages)
- FGE-series (4 pages)
- FGV-series (4 pages)
- FGE-H-series (4 pages)
- FGV-H-series (4 pages)
- MF Series (2 pages)
- MFD_Series (2 pages)
- FGS-100E (20 pages)
- FGS-100-PXL (7 pages)