beautypg.com

Profibus dp, 4 technical data – KROHNE UFC 400 PROFIBUS PA-PROFIBUS DP User Manual

Page 8

background image

2

PROFIBUS DP

8

UFC 400

www.krohne.com

05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en

2.4 Technical data

Hardware

Type

PROFIBUS RS485 interface according to IEC 61158-2

Connection

Dependent of polarity; please note at electrical connection!

Software

GSD

GSD file on CD-ROM or from internet site

Supported GSD:

KR014520.GSD

PA039741.GSD

Device profile

PROFIBUS PA Profile 3.02; conformance class B, compact

Address range

0…126 (default 126)

0…125 via PROFIBUS service set_slave_add

0…126 via local display

126 via factory_reset = 2712

Local control

Local display and operator interface at device

SAPs

2 x MS1 SAPs – acyclic interface to PLC

3 x MS2 SAPs – the number of MS2 Service Access Points is typically

equal to the maximum number of master class 2 tools

Function blocks

1 x TB = Transducer Block

1 x PB = Physical Block

6 x AI = Analog Input Blocks

3 x TOT = Totalizer Function Blocks