PROFIBUS SETTINGS

5

49

UFC 400

www.krohne.com

05/2014 - 4003118502 - AD UFC 400 PROFIBUS R02 en

C5.1 Device Info

C5 Device

In this menu all functions are grouped that have no effect on the measurement or any output directly.

C5.1.1

Tag

Tag descriptor of the physical block of the PROFIBUS module will be

displayed. The Tag descriptor provides an application specific reference to

the blocks. It will be assigned by the user of the device. The Tag descriptor is

an octet string (a visible string will be preferred) consisting of 32 byte. The

first 21 characters will be displayed only!

C5.3

1st Meas. Page

C5.3.1

Function

Specify number of measured value lines (font size)

One Line / Two Lines / Three Lines

C5.3.2

Measurement Line 1

Select the measurement of the 1st line:

Select:

Volume Flow / Velocity of Sound / Mass Flow / Flow Speed / Gain / SNR /

Diag. Flow Speed / Diag. Velocity of Sound / Diag. Gain / Diag. SNR

C5.3.8

Measurement Line 2

Specify measurement of 2nd line (only available if this Line 2 is activated)

Select:

Bargraph / Volume Flow / Velocity of Sound / Mass Flow /

Flow Speed / Gain / SNR / Diag. Flow Speed / Diag. Velocity of Sound /

Diag. Gain / Diag. SNR / FB3 Total. 1 Volume / FB3 Total. 1 Mass /

FB4 Total. 2 Volume / FB4 Total. 2 Mass /

FB5 Total. 3 Volume / FB5 Total. 3 Mass / Operating Hours

C5.3.10

Measurement Line 3

Specify measurement of 3rd line (only available if this Line 3 is activated)

Select:

Volume Flow / Velocity of Sound / Mass Flow / Flow Speed / Gain / SNR /

Diag. Flow Speed / Diag. Velocity of Sound / Diag. Gain / Diag. SNR /

FB3 Total. 1 Volume / FB3 Total. 1 Mass /

FB4 Total. 2 Volume / FB4 Total. 2 Mass /

FB5 Total. 3 Volume / FB5 Total. 3 Mass / Operating Hours

C5.4

2. Meas. page

Setting of the measurement for the second measuring page.

For PROFIBUS devices this page shows only the PROFIBUS values

FB1…FB8.

C5.4.1

C5.4.3

C5.4.5

Measurement Line 1

Measurement Line 2

Measurement Line 3

Select the measurement of the 1st, 2nd and 3rd line:

FB1 Analog inp. 1 / FB2 Analog inp. 2 / FB3 Totaliser 1 / FB4 Totaliser 2 /

FB5 Totaliser 3 / FB6 Analog inp. 3 / FB7 Analog inp. 4 / FB8 Analog inp. 5 /

FB9 Analog inp. 6

C5.4.2

C5.4.4

C5.4.6

Format 1.line

Format 2.line

Format 3.line

Fixed number of digits after the decimal point or automatic, where the

number of digits is automatically adjusted to the available space.

C5.8

Physical Block

This menu is only available, if a PROFIBUS interface is present.

C5.8.1

Station Address

Selects the PROFIBUS station address of the device.

The PROFIBUS address can also be changed using the PROFIBUS service

"set_slave_add". The input range is 0...125 according to the PROFIBUS

specification. Address 126 is the default address and cannot be set via the

PROFIBUS service "set_slave_add" - use menu instead to reset to default

address.

C5.8.7

Information

Available if there is a PROFIBUS interface in existence; the below mentioned

information will be displayed about the PROFIBUS interface:

Hardware Revision of the PROFIBUS interface used

Software Version of the PROFIBUS interface used

Date of Compilation

(same as B3.5)

C5.8.2

Diag. extension

Content of the PROFIBUS diagnosis extension is displayed.

C5.8.3

Diag. extension i

Content of the internal diagnosis extension is displayed.