HI_HI_ALM

HI_HI_ALM

HI_HI_ALM

HI_HI_ALM

High High Alarm

High High Alarm

High High Alarm

High High Alarm

Mix

The status for High High Alarm and its associated time stamp.

Settings of 5 subelements see in the following part.

-

Settings of 5 subelements for previous 2 parameters High Alarm and High High Alarm:

Unacknowledged

R/W

Setting:

Uninitialized / Acknowledged / Unacknowledged

Uninitialized

Alarm State

R

Setting:

Uninitialized / Clear - reported / Clear - not reported / Active -

reported / Active - not reported

Uninitialized

Time Stamp

R

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Uninitialized

Subcode

R

Setting:

Other / Block Configuration / Link Configuration / Simulation

Active / Local Override / Device Fault State / Device

Maintenance / Input Failure / Output Failure / Memory

Failure / Lost Static Data / Lost NV Data / Readback Check /

Maintenance Needed / Power Up / Out Of Service

Other

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

0.0

HI_HI_LIM

HI_HI_LIM

HI_HI_LIM

HI_HI_LIM

High High Limit

High High Limit

High High Limit

High High Limit

R/W

The setting for High High Alarm in engineering units.

Setting range see in the following part.

100

HI_HI_PRI

HI_HI_PRI

HI_HI_PRI

HI_HI_PRI

High High Priority

High High Priority

High High Priority

High High Priority

R/W

Priority of the High High Alarm.

Setting see in the following part.

0

HI_LIM

HI_LIM

HI_LIM

HI_LIM

High Limit

High Limit

High Limit

High Limit

R/W

The setting for High Alarm in engineering units.

Setting range see in the following part.

95

HI_PRI

HI_PRI

HI_PRI

HI_PRI

High Priority

High Priority

High Priority

High Priority

R/W

Priority of the High Alarm.

Setting see in the following part.

1

Setting range for previous 2

parameters:

x_y_LIM

x_y_Limit

-3.39 E38…+3.39 E38 / - INF (- infinite) / + INF (+ infinite)

Setting for previous 2

parameters:

x_y_PRI

x_y_Priority

0: The associated alert may clear when the priority is changed

to 0, but it will never occur.

1: The associated alert is not send as a notification. If the

priority is above 1, then the alert must be reported.

2: Reserved for alerts that do not require the attention of a

plant operator, e.g. diagnostic and system alerts. Block alarm,

error alarm and update event have a fixed priority of 2.

3...7: Increasing higher priorities - advisory alarms.

8...15: Increasing higher priorities - critical alarms.

0

IO_OPTS

IO_OPTS

IO_OPTS

IO_OPTS

IO Options

IO Options

IO Options

IO Options

(IO = Input/Output)

(IO = Input/Output)

(IO = Input/Output)

(IO = Input/Output)

R/W

Options which the user may select to alter input and output

block processing.

0 (no option

enabled)

L_TYPE

L_TYPE

L_TYPE

L_TYPE

L_Type

L_Type

L_Type

L_Type

Linearization)

Linearization)

Linearization)

Linearization)

R/W

Determines if the values passed by the TB to the AI block may

be used directly (Direct) or if the value is in different units and

must be converted linearly (Indirect) or with square root (Ind

Sqr Root), using the input range defined by the transducer and

the associated output range.

W = Writeable only by setting "OOS" in MODE_BLK

Uninitialized

Setting:

Uninitialized / Direct / Indirect / Ind Sqr Root

LO_ALM

LO_ALM

LO_ALM

LO_ALM

Low Alarm

Low Alarm

Low Alarm

Low Alarm

Mix

The status for Low Alarm and its associated time stamp.

Settings of 5 subelements see in the following part.

-

Parameter

Parameter

Parameter

Parameter
Subelement

Access

Description and settings

Initial Value