Operation – KROHNE IFC 300 Converter FOUNDATION FIELDBUS EN User Manual

Page 20

background image

4

OPERATION

20

IFC 300

www.krohne.com

02/2011 - 4001086501 - AD IFC 300 FF R02 en

DIAGNOSIS_DEV

DIAGNOSIS_DEV

DIAGNOSIS_DEV

DIAGNOSIS_DEV

Diagnosis Device

Diagnosis Device

Diagnosis Device

Diagnosis Device

R

Display of maximum 8 (error) messages.

Current diagnosis

Setting:

0:Startup phase / 255:no message

F:

F:

F:

F: error in device / IO 1 / parameter / IO 2 / configuration /

display / sensor electronics / sensor global / sensor local /

field current local / current output A / current output B /

current output C / software user interface / hardware

settings / hardware detection / RAM/ROM error IO 1 /

RAM/ROM error IO 2 / fieldbus / application error sensor /

empty pipe / flow exceeding limit / field frequency too high /

DC offset / open circuit A / open circuit B / open circuit C /

over range A (current) / over range B (current) / over range C

(current) / over range A (pulse) / over range B (pulse) / over

range D (pulse) / over range display 1 / over range display 2 /

active settings / factory settings / backup 1 settings / backup 2

settings

S:

S:

S:

S: out of specification / uncertain measurement / pipe not

full / empty pipe / linearity / flow profile / electrode noise /

gain error / electrode symmetry / field coil broken / field coil

bridged / field current deviation / field frequency too high /

electronic temperature / field coil temperature / overflow

counter 1 -FB2 / overflow counter 2 -FB3 / backplane invalid /

overflow counter 1 / overflow counter 3 -FB4 / checks in

progress

C:

C:

C:

C: test sensor / simulation fieldbus

I:

I:

I:

I: counter 1 stopped-FB2 / counter 2 stopped-FB3 / power

fail / counter 1 stopped / counter 3 stopped-FB4 / power fail /

control input A active / control input B active / over range

display 1 / over range display 2 / backplane sensor /

backplane settings / backplane difference / optical interface /

write cycles overfl. / baudrate search / no data exchange /

conductivity off / diagnosis channel off / empty pipe

Current diagnosis

DISPLAY_CNFG

DISPLAY_CNFG

DISPLAY_CNFG

DISPLAY_CNFG

Display Configuration

Display Configuration

Display Configuration

Display Configuration

R/W

Select the function block output value to display at which line.

For details see subelements.

-

DISP_LINE1

Display Line 1

Setting:

AI1 / AI2 / AI3 / PID / INT1 / INT2

AI1

DISP_LINE2

Display Line 2

AI2

DISP_LINE3

Display Line 3

AI3

ELECTRONIC_INFO

ELECTRONIC_INFO

ELECTRONIC_INFO

ELECTRONIC_INFO

Electronic Information

Electronic Information

Electronic Information

Electronic Information

R

Information about ident number, electronic revision and

production date. For details see subelements.

-

IDENT_NUMBER

Ident Number

Actual ident number

ELECTRONIC_REV

Electronic Revision

Actual electronic revision

PRODUCTION_DATE

Production Date

Date of production

Parameter

Parameter

Parameter

Parameter
Subelement

Access

Description and settings

Initial Value