Operation – KROHNE IFC 300 Converter FOUNDATION FIELDBUS EN User Manual
Page 27
OPERATION
4
27
IFC 300
www.krohne.com
02/2011 - 4001086501 - AD IFC 300 FF R02 en
PRIMARY_VALUE_1_
PRIMARY_VALUE_1_
PRIMARY_VALUE_1_
PRIMARY_VALUE_1_
RANGE
RANGE
RANGE
RANGE
Primary Value 1 Range
Primary Value 1 Range
Primary Value 1 Range
Primary Value 1 Range
R
The high and low range limit values, the engineering units
code and the number of digits to the right of the decimal point
to be used to display the Primary Value.
-
EU_100
Engineering Unit 100
R
The engineering unit value which represents the upper end of
range of the associated Block Parameter.
-
EU_0
Engineering Unit 0
R
The engineering unit value which represents the lower end of
range of the associated Block Parameter.
-
UNITS_INDEX
Inits Index
R
Device Description units code index for the engineering unit
descriptor for the associated block value.
-
DECIMAL
Decimal (Point)
R
The number of digits to the right of the decimal point which
should be used by an interface device in displaying the
specified parameter.
0
Setting:
0...255
SELF_TEST_C1_3
SELF_TEST_C1_3
SELF_TEST_C1_3
SELF_TEST_C1_3
R/W
Self test (Fct. C1.3)
-
Empty_Pipe
R/W
empty pipe detect (Fct. C1.3.1)
0
Setting:
0: off / 1: conductivity / 2: cond. & empty pipe (S) / 3: cond. &
empty pipe (F)
Limit_Empty_Pipe
R/W
limit empty pipe (Fct. C1.3.2)
0.006
Setting:
0.0…0.9999
Full_Pipe
R/W
full pipe detect (Fct. C1.3.4)
0
Setting:
0: off / 1: on
Limit_Full_Pipe
R/W
limit full pipe (Fct. C1.3.5)
0.006
Setting:
0.0…0.9999
Linearity
R/W
linearity (Fct. C1.3.6)
0
Setting:
0: off / 1: on
Gain
R/W
gain (Fct. C1.3.8)
0
Setting:
0: off / 1: on
Coil_Current
R/W
coil current (Fct. C1.3.0)
0
Setting:
0: off / 1: on
Flow_Profile
R/W
flow profile (Fct. C1.3.10)
0
Setting:
0: off / 1: on
LimitFlowProfile
R/W
limit flow profile (Fct. C1.3.11)
0
Setting:
0: off / 1: on
Electrode_Noise
R/W
electrode noise (Fct. C1.3.13)
0
Setting:
0: off / 1: on
LimitElectrNoise
R/W
limit electrode noise (Fct. C1.3.14)
0.1
Setting:
0.0...12.0
Parameter
Parameter
Parameter
Parameter
Subelement
Access
Description and settings
Initial Value
.book Page 27 Tuesday, January 18, 2011 3:40 PM