Relative Index

R

The OD index of the static parameter whose change caused

this alert, minus the FB starting index. If the update event was

caused by a write to multiple parameters at the same time,

then this attribute will be zero.

0

Setting:

0…65535

WRITE_ALM

WRITE_ALM

WRITE_ALM

WRITE_ALM

Write Alarm

Write Alarm

Write Alarm

Write Alarm

Mix

This alert is generated if the write lock parameter is cleared.

-

Unacknowledged

R/W

A discrete enumeration which is set to "Unacknowledged"

when an alarm occurs, and set to "Acknowledged" by a write

from a human interface device or other entity which can

acknowledge that the alarm/event has been noticed.

Uninitialized

Setting:

Uninitialized / Acknowledged / Unacknowledged

Alarm State

R

A discrete enumeration which gives an indication of whether

the alert is active and whether it has been reported.

Uninitialized

Setting:

Uninitialized / Clear - reported / Clear - not reported / Active -

reported / Active - not reported

Time Stamp

R

The time when evaluation of the block was started and a

change in alarm/event state was detected that is unreported.

The time stamp value will be maintained constant until alert

confirmation has been received - even if another change of

state occurs.

Uninitialized

Setting:

MM / DD / YY (Month / Day / Year)

HH:MM:SS (Hour:Minute:Second)

Subcode

R

An enumeration specifying the cause of the alert to be

reported.

Other

Setting:

Other / Block Configuration / Link Configuration / Simulation

Active / Local Override / Device Fault State / Device

Maintenance / Input Failure / Output Failure / Memory

Failure / Lost Static Data / Lost NV Data / Readback Check /

Maintenance Needed / Power Up / Out Of Service

Discrete Value

R

The value of the associated parameter at the time the alert

was detected.

State 0

Setting:

Discrete State 0...16

WRITE_LOCK

WRITE_LOCK

WRITE_LOCK

WRITE_LOCK

Write Lock

Write Lock

Write Lock

Write Lock

R/W

If set, no writes from anywhere are allowed, except to clear

WRITE_LOCK. Block inputs will continue to be updated.

Not locked

Setting:

Uninitialized / Not locked / Locked

WRITE_PRI

WRITE_PRI

WRITE_PRI

WRITE_PRI

Write Priority

Write Priority

Write Priority

Write Priority

R

Priority of the alarm generated by clearing the write lock.

0

Setting:

0...15

Parameter

Parameter

Parameter

Parameter
Subelement

Access

Description and settings

Initial Value