beautypg.com

Electrical connections, 2 description of the cg number – KROHNE IFC 300 Converter Quickstart EN User Manual

Page 56

background image

3

ELECTRICAL CONNECTIONS

56

IFC 300

www.krohne.com

08/2010 - 4000070303 - QS IFC 300 R06 en

3.9.2 Description of the CG number

The last 3 digits of the CG number (5, 6 and 7) indicate the assignment of the terminal
connections. Please see the following examples.

Examples for CG number

Description of abbreviations and CG identifier for possible optional modules
on terminals A and B

Figure 3-38: Marking (CG number) of the electronics module and input/output variants

1 ID number: 0
2 ID number: 0 = standard; 9 = special
3 Power supply option / measuring sensor option
4 Display (language versions)
5 Input/output version (I/O)
6 1st optional module for connection terminal A
7 2nd optional module for connection terminal B

CG 300 11 100

100...230 VAC & standard display; basic I/O: I

a

or I

p

& S

p

/C

p

& S

p

& P

p

/S

p

CG 300 11 7FK

100...230 VAC & standard display; modular I/O: I

a

& P

N

/S

N

and optional module P

N

/S

N

& C

N

CG 300 81 4EB

24 VDC & standard display; modular I/O: I

a

& P

a

/S

a

and optional module P

p

/S

p

& I

p

Abbreviation

Identifier for CG No.

Description

I

a

A

Active current output

I

p

B

Passive current output

P

a

/ S

a

C

Active pulse, frequency, status output or limit switch (changeable)

P

p

/ S

p

E

Passive pulse, frequency, status output or limit switch (changeable)

P

N

/ S

N

F

Passive pulse, frequency, status output or limit switch according to

NAMUR (changeable)

C

a

G

Active control input

C

p

K

Passive control input

C

N

H

Active control input to NAMUR

Signal converter monitors cable breaks and short circuits acc. to

EN 60947-5-6. Errors indicated on LC display. Error messages possible

via status output.

IIn

a

P

Active current input

IIn

p

R

Passive current input

-

8

No additional module installed

-

0

No further module possible