beautypg.com

Electrical connections, 6 length of signal cable b – KROHNE IFC 300 Converter Quickstart EN User Manual

Page 24

background image

3

ELECTRICAL CONNECTIONS

24

IFC 300

www.krohne.com

08/2010 - 4000070303 - QS IFC 300 R06 en

3.4.6 Length of signal cable B

INFORMATION!
For temperatures of the medium above 150

°

C / 300

°

F, a special signal cable and a ZD

intermediate socket are necessary. These are available including the changed electrical
connection diagrams.

Measuring sensor

Nominal size

Min. electrical
conductivity
[µS/cm]

Curve for signal
cable B

DN [mm]

[inch]

OPTIFLUX 1000 F

10...150

3/8...6

5

B2

OPTIFLUX 2000 F

25...150

1...6

20

B3

200...2000

8...80

20

B4

OPTIFLUX 4000 F

2.5...6

1/10...1/6

10

B1

10...150

3/8...6

1

B3

200...2000

8...80

1

B4

OPTIFLUX 5000 F

2.5

1/10

10

B1

4...15

1/6...1/2

5

B2

25...100

1...4

1

B3

150...250

6...10

1

B4

OPTIFLUX 6000 F

2.5...15

1/10...1/2

10

B1

25...150

1...6

1

B3

WATERFLUX 3000 F

25...600

1...24

20

B1

Figure 3-8: Maximum length of signal cable B

1 Maximum length of signal cable B between the measuring sensor and signal converter [m]
2 Maximum length of signal cable B between the measuring sensor and signal converter [ft]
3 Electrical conductivity of the medium being measured [μS/cm]