B-20
BOP-1K 070212
B.72 [SOURce:]LIST:SET:SAMPle COMMAND
LIST:SET:SAMP
Syntax:
Short Form: LIST:SET:SAMP value
Long Form: LIST:SET:SAMPle value
where value = sample pulse duration, between 0.00025 and 0.034 (Seconds)
Description: Establishes sample pulse duration. This command must be used when measuring a sample, but
must only be issued once, otherwise a -100 “command error: will result. (See Figures B-6 and B-7.)
B.73 [SOURce:]LIST:SET:SAMPle? QUERY
LIST:SET:SAMP?
Syntax:
Short Form: LIST:SET:SAMP?
Long Form: LIST:SET:SAMPle?
Returns:
Description: Returns sample pulse duration. Returns sample pulse duration set by LIST:SET:SAMP command,
between 0.00025 and 0.034 Second.
If
sample pulse duration
has not been set, error 100- “com-
mand error” results.
B.74 [SOURce:]LIST:SET:TRIGger COMMAND
LIST:SET:TRIG
Syntax:
Short Form: LIST:SET:TRIG
Description: Enables the output trigger and establishes pulse-width. Used to establish EXT_C (pin 5) and
EXT_E (pin 6) of External Protection port as an output trigger instead of an output off flag. Once
LIST:SET:TRIG is sent, these pins function as an output trigger (see Table 2-4) until LIST:CLE (PAR.
B.49) is sent, restoring the function to output off flag. See Figure B-7 for example. The pulse width,
between 0.00025 to 0.034 (Seconds) is established by
across EXT PROTECT PORT pins 5 and 6 is on (conducting) while pulse is active. When
= OFF, the transistor across EXT PROTECT PORT pins 5 and 6 is off while pulse is active.
B.75 [SOURce:]LIST:SET:TRIGger? QUERY
LIST:SET:TRIG?
Syntax:
Short Form: LIST:SET:TRIG?
Long Form: LIST:SET:TRIGger?
Returns
Description: Returns trigger pulse-width. If trigger pulse duration has not been set, error 100- “command error”
results
.
B.76 [SOURce:]LIST:SET:WAIT COMMAND
LIST:SET:WAIT
Syntax:
Short Form: LIST:SET:WAIT value
Long Form: LIST:SET:WAIT value
where:
Description: Establishes the time-out for a wait command. If this command is not sent, the time out period will
be 0 indicating an infinite wait time. (See Figures B-6 and B-7.)
B.77 [SOURce:]LIST:SET:WAIT? QUERY
LIST:SET:WAIT?
Syntax:
Short Form: LIST:SET:WAIT?
Long Form: LIST:SET:WAIT?
Returns
Description: Returns the time-out for a wait command. Returns 0 if LIST:SET:WAIT not sent, indicating infinite wait
time.