beautypg.com

2 test equipment requirements, Test equipment requirements -2 – KEPCO BOP 1KW-MG Operator Manual, Firmware Ver.4.08 to 4.11 User Manual

Page 134

background image

4-2

BOP-1K 070212

4.2

TEST EQUIPMENT REQUIREMENTS

Table 4-2 lists sense resistors recommended for measuring current and includes Kepco and
Manufacturer’s part numbers. The value of the sense resistor chosen should be known with
0.001% accuracy. If other than a recommended sense resistor is to be used, it must be rated for
at least 100W power dissipation (actual power dissipation will be approximately 10W). The ther-
mal coefficient of the sense resistor chosen should be 10 ppm/°C or better.

CURRENT,
INTERNAL

1. ZERO
2. POSITIVE
3. NEGATIVE

Internal

Output Current:
1. 0.0A
2. +Current FS
3. –Current FS

Short with Meas.
Shunt
Automatic CM

1. DVM between probe
terminals of Meas.
Shunt (LO towards COM
S)
2. Adjust for zero, posi-
tive and negative FS

CURRENT,
PROTECTION

1. POSITIVE
2. NEGATIVE

Internal

Output Current:
1. +Current FS
2. -Current FS

Short with Meas.
Shunt
Automatic VM

1. DVM between probe
terminals of Meas.
Shunt (LO towards COM
S)
2. Adjust for positive and
negative FS.

CURRENT,
EXTERNAL

1. ZERO
2. POSITIVE

External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pin 11 ref to pin 10)

Output Current:
1. 0.0A
2. +Current FS

Short with Meas.
Shunt
Automatic CM

1. DVM between probe
terminals of Meas.
Shunt (LO towards COM
S).
2)Adjust for zero, pos
FS.

CURRENT,
GAIN

1. ZERO
2. POSITIVE

External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pin 11 ref to pin 10)

Output Current:
1. 0.0A
2. 0.0A

Short with Meas.
Shunt
Automatic CM

1. DVM between probe
terminals of Meas.
Shunt (LO towards COM
S)
2. Adjust for zero
(both Zero and Positive)

EXTERNAL
CONTROLS,
PARALLEL

1. ZERO
2. POSITIVE

External:
1. 0.0V
2. +10.0V
(Par/Ser CTRL-IN
Port pin3 ref. to
pin1)

Output Current:
1. 0.0A
2. +Current FS

Short with Meas.
Shunt
Automatic CM

1. DVM between probe
terminals of Meas.
Shunt (LO towards COM
S)
2. Adjust for zero, pos.
FS
3. Calibrate unit for
Slave in Parallel

EXTERNAL
CONTROLS,
I_OUT

1. ZERO
2. POSITIVE

INTERNAL

Voltage at Par/Ser
CTRL-IN Port pin 6
ref. to pin1:
1. 0.0V
2. +10.0V

Short with Meas.
Shunt
Automatic CM

1. DVM at Par/Ser
CTRL-IN Port pin 6 ref.
to pin 1
2. Adjust for zero,
+10.0V
3. Calibrate unit for Mas-
ter in Parallel

EXTERNAL
PROTECTION,
Pos. Voltage
Neg. Voltage
Pos. Current
Neg. Current
(together)

1. ZERO
2. FULL SCALE

External:
1. 0.0V
2. +10.0V
(Analog I/O Port
pins 14, 6, 13, 5 ref
to pin12)

N/A

No requirements

Automatic internal
measurement

TABLE 4-1. CALIBRATION SUMMARY (CONTINUED)

Type

Step

Reference Type and

Value

Monitored Parameter

Output Conditions

Notes