B-12
BOP-1K 070212
B.38 [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH]? QUERY
CURR:PROT:LIM:[:BOTH]?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM[:BOTH]?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit[:BOTH]?
Returns
Description: Identifies the maximum value possible for protection limits for current (positive, negative); maximum is
1% greater than rated output current.
B.39 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative COMMAND
CURR:PROT:LIM:NEG
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:NEG
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative
where
current.
Description: Establishes the minimum (maximum absolute) value possible for the negative protection limit for cur-
rent. This may be set up to 1% greater than rated current. Requires MEM:UPD (PAR. B.12) to save for
power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.40 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative? QUERY
CURR:PROT:LIM:NEG?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:NEG?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:NEGative?
Returns:
Description: Identifies the minimum (maximum absolute) value possible for the negative protection limit for current.
B.41 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive COMMAND
CURR:PROT:LIM:POS
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:POS
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive
where
current.
Description: Establishes the maximum value possible for the positive protection limit for current. This may be set
up to 1% greater than rated current. Requires MEM:UPD (PAR. B.12) to save for power up. See PAR.
3.5.2.2 and Figure 3-16 for special programming considerations.
B.42 [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive? QUERY
CURR:PROT:LIM:POS?
Syntax:
Short Form: [SOUR:]CURR[:LEV]:PROT:LIM:POS?
Long Form: [SOURce:]CURRent[:LEVel]:PROTect:LIMit:POSitive?
Returns:
Description:Identifies the maximum value possible for the positive protection limit for current.
B.43 [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] COMMAND
CURR:TRIG
Syntax:
Short Form: [SOUR:]CURR[:LEV]:TRIG[:AMP]
Long Form: [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude]
Description: Programs current value to be transferred to output by *TRG (trigger) commands. This command
can be used to reset many power supplies to preselected parameters by issuing a single *TRG com-
mand. Actual output current will depend on load conditions. If the value exceeds the maximum for the
model being programmed, error message -222,”Data out of range” is posted in output queue. Related
Commands: CURR, *TRG, TRIG