Din rail mounting the enclosure, Placing dome connectors and plugs in the enclosure – In-Situ Con TROLL PRO Installation Manual (purchased after 10 May 2012) User Manual
Page 14
14
DIN Rail Mounting the Enclosure
Each rail mount clip is secured to the enclosure with a supplied #6 screw.
1. With the enclosure open, drop 1 screw into each drilled corner of the box.
2. Use a long screwdriver to push the screw through the back of the enclosure.
3. Place the DIN clip on the top of the enclosure. See Figure 3.12 .
4. Use a long screwdriver to tighten the screw to the clip.
5. Repeat steps 2-4 for the remaining screw and clip.
6. Mount on a DIN rail.
Figure 3.11 Placing the screw in the enclosure
Figure 3.12 Securing the screw to the DIN clip
Placing Dome Connectors and Plugs in the Enclosure
When installed as directed, this product is rated IP-67 and can withstand temporary
immersion in up to 1 meter of water. To meet the IP-67 rating, the following conditions
must be met.
l
The lid must be completely closed and screwed down.
l
The 6 ports must be plugged with either cord grips and cables, port plugs, or a
combination of both.
l
Additionally, O-rings must be used as described below.
Attach plugs and dome connectors to the enclosure using the following steps.
1. Place a large O-ring over the threaded end of the plug or dome connector.
2. Screw the threaded end of the plug or dome connector through the bottom of the
enclosure. Tighten it to “snug” and then an turn it an additional half turn.