13.4 Displayed warnings

Displayed warnings

Symptom

Cause

Solution

Remark

Q/T sensor not

correctly connected

Lead(s) loosened or

incorrectly connected

Appliance runs, but displays a warning

1. Properly connect Q/T sensor and the warning will disappear
2. If correctly wired but the warning remains, replace sensor
Note: To have the sensor connected or replaced, contact your

installation engineer

Collector temperature

excessive

Temperature S1 is

higher than T

collector

max

The pump in the solar circuit switches off, until S1 < 70°C

1. You can let the message disappear automatically by allowing

the heating fluid to cool down

2. You can also manually eliminate the message by pressing the

RESET and ENTER button simultaneously

Maximum burning

hours: Service required

The actual burning

hours have exceeded

the preset burning

hours

Appliance runs, but displays a warning

For maintenance to your appliance, contact your installation

engineer