beautypg.com

A.O. Smith 30 User Manual

Page 91

background image

is

Instruction manual SGS

91

F10 (lock out error)

Restriction on the

number of ignition

attempts based on

pressure switch state

changes.

Pressure switch not

closing

1. Check the running speed of the fan

(12.5 "Display the selected

appliance")

2. Check that the hoses on the pressure switch and the air supply

hose between fan and burner are correctly fitted. Refit them if
necessary

3. Check for cracks in the hoses on the pressure switch and in the

air supply hose between fan and burner. If necessary, replace
the hoses.

4. Check that the flue gas outlet is compliant

(3.10 "Air supply and

flue")

.

5. Check for blockage in the flue gas discharge. Remove any

blockage that may be present

6. Check for blockage in the condensation water discharge.

Remove any blockage that may be present.

7. Measure the pressure differential across the pressure switch.

See the table in Preparation for
maintenance

(15.2 "Preparation for maintenance")

. If there is

insufficient pressure differential, clean the heat exchanger. If the
pressure differential is acceptable, check that the pressure
switch is closing, using a multimeter.

If the error cannot be resolved or is persistent, contact your

installation engineer
To replace the necessary parts, you must contact your installation

engineer

F11 (blocking error)

Flame detection with

closed gas valve.

Defective gas valves

See F07.

F17 (blocking error)

Communication error

No power supply at

solar controller

1. Check that there is power to the solar heating system controller
2. The measured voltage must be 230VAC (-15%, +10%)

See the SGS electrical diagram

(17 "Appendices")

If the error persists, consult your installation engineer

No cable or damaged

cable

1. Check the wiring (communication cable) between the main

controller and the solar heating system controller

2. If cable missing, connect the cable
3. If cable damaged, replace the cable

See the SGS electrical diagram

(17 "Appendices")

For replacement of the cable, contact your installation engineer

Code + Description

Cause

Solution

Remark