beautypg.com

A.O. Smith 30 User Manual

Page 90

background image

is

Instruction manual SGS

90

F06 (lock out error)

Short circuit between

flame probe and earth

Damaged cable in

contact with metal

surface.

Check the wiring of the flame probe. If necessary, replace the

wiring.

If the error persists, contact your installation engineer.
To replace the necessary parts, you must contact your installation

engineer

Ceramic part of the

flame probe is

broken/cracked.

1. Check that the ceramic part of the flame probe is still intact in

the vicinity of the burner's air distribution plate.

2. If not, the flame probe must be replaced.

F07 (lock out error)

A flame has been

detected after the gas

valve was closed.

Defective gas valves

1. Check whether there is still burner pressure present after the

gas valves have closed.

2. Check whether a flame is still present after the gas valves have

closed.

3. If this is the case, the gas control must be replaced.

If the error cannot be resolved or is persistent, contact your

installation engineer
To replace the necessary parts, you must contact your installation

engineer

F08 (lock out error)

Error message from

safety relay

Flame detection before

the gas valve opened.

1. Reset the electronic controller.
2. If the error reappears, replace the electronic controller.

If the error cannot be resolved or is persistent, contact your

installation engineer
To replace the necessary parts, you must contact your installation

engineer

F09 (lock out error)

Water temperature

safety.

The temperature at the

top of the tank exceeds

93

o

C.

1. Check that the circulation pump (if present) is working
2. Check the position of the temperature sensor T

1

.

3. Reset appliance controller

If the error cannot be resolved or is persistent, contact your

installation engineer

Code + Description

Cause

Solution

Remark