Installation

26

Instruction manual SGS

3

is

3.4.3

Gas data

Gas data

Description II

2H3+

Unit

SGS
28

SGS
30

SGS
50

SGS
60

Gas category 2H: G20 - 20 mbar
Injector orifice diameter

mm

4.90

5.10

7.00

7.10

(1) = Blank plate
(2) = Burner pressure regulator

1 or 2

2

2

2

2

Nominal load (gross calorific value)

kW

32.1

34.5

52.6

63.2

Nominal output

kW

30.5

32.7

48.8

59.6

Supply pressure

mbar

20

20

20

20

Burner pressure

mbar

8.5

8.5

8.5

11.5

Gas consumption

(*)

m

3

/h

3.1

3.3

5.0

6.0

General 3+
Injector orifice diameter

mm

2.50

2.60

3.40

3.80

(1) = Blank plate
(2) = Burner pressure regulator

1 or 2

1

1

1

1

Gas category: G30-30 mbar (butane)
Nominal load (gross calorific value)

kW

30.7

32.8

50.6

59.4

Nominal output

kW

29.8

31.8

48.1

57.4

Supply pressure

mbar

30

30

30

30

Burner pressure

(†)

mbar

-

-

-

-

Gas consumption

(*)

kg/h

2.2

2.4

3.7

4.3

Gas category: G31-37 mbar (propane)
Nominal load (gross calorific value)

kW

29.0

30.9

50.3

59.1

Nominal output

kW

28.1

29.8

47.7

56.9

Supply pressure

mbar

37

37

37

37

Burner pressure

(†)

mbar

-

-

-

-

Gas consumption

(*)

kg/h

2.1

2.2

3.6

4.2

(*) Based on 1013.25 mbar and 15 °C.
(†) If using a blank plate instead of a burner pressure regulator, it is assumed that the burner pressure is equal to

the supply pressure. In practice, however, the burner pressure will be lower.