beautypg.com

Caution, Turn on the instrument, Press the arrow keys to select lan – HT instruments М75 User Manual

Page 23

background image

M72 - M73 - M74 - M75

EN - 21

4.11. LAN:

CABLING TEST (M75)

CAUTION

Before taking any measurement make sure that the circuit under test is not
powered. Connections to phone lines or active networks could damage the
instrument.

Fig. 8: Connections of the instrument’s terminals during LAN tests

1. Turn on the instrument

2. Press the arrow keys to select LAN

3. Select the type of cable under test by pressing MODE/PEAK: set STP whether

shielded, UTP whether unshielded

4. Connect the cable under test to the instrument and to the remote unit if necessary

through patch cables (see Fig. 8)

CAUTION

The remote unit must be necessarily connected to the other end of the cable
being tested, otherwise no measurement is performed.

5. Press GO to perform all tests related to the selected type of cable

6. If cabling is correct, a screen like this is

displayed. The identification number (02)
refers to the remote unit connected to the
other end of the cable being tested

Identification number
of the remote unit

This manual is related to the following products: