beautypg.com

Afg-2225 quick start guide – GW Instek AFG-2225 Quick Start Guide User Manual

Page 54

background image

AFG-2225 Quick Start Guide

52

FSK

Carrier Waveforms

Sine, Square,
Ramp,Pulse

Sine, Square,
Ramp,Pulse

Modulating
Waveforms

50% duty cycle square 50% duty cycle square

Modulation Rate

2mHz to 100 kHz
(INT)
DC to 100 kHz(EXT)

2mHz to 100 kHz
(INT)
DC to 100 kHz(EXT)

Frequency Range

1uHz to Max
Frequency

1uHz to Max
Frequency

Source

Internal / External

Internal / External

PM

Carrier Waveforms

Sine, Square, Ramp

Sine, Square, Ramp

Modulating
Waveforms

Sine, Square, Triangle,
Upramp, Dnramp

Sine, Square, Triangle,
Upramp, Dnramp

Modulation
Frequency

2mHz to
20kHz (Int)
DC to 20kHz (Ext)

2mHz to
20kHz (Int)
DC to 20kHz (Ext)

Phase deviation

0˚ to 360˚

0˚ to 360˚

Source

Internal / External

Internal / External

SUM

Carrier Waveforms

Sine, Square,
Ramp,Pulse,Noise

Sine, Square,
Ramp,Pulse,Noise

Modulating
Waveforms

Sine, Square, Triangle,
Upramp,Dnramp

Sine, Square, Triangle,
Upramp,Dnramp

Modulation
Frequency

2mHz to
20kHz (Int)
DC to 20kHz (Ext)

2mHz to
20kHz (Int)
DC to 20kHz (Ext)

SUM
Depth

0% to 100.0%

0% to 100.0%

Source

Internal / External

Internal / External

External Trigger Input

Type

For FSK, Burst, Sweep

Input Level

TTL Compatibility

Slope

Rising or Falling(Selectable)

Pulse Width

>100ns

Input Impedance

10kΩ,DC coupled

External Modulation Input

Type

For AM, FM, PM, SUM

Voltage Range

±5V full scale

Input Impedance

10kΩ

Frequency

DC to 20kHz

Trigger Output

Type

For Burst, Sweep, Arb

Level

TTL Compatible into 50Ω

Pulse Width

>450ns

Maximum Rate

1MHz

Fan-out

≥4 TTL Load

Impedance

50Ω Typical

Dual Channel Function

Phase

-180˚ ~180˚