18

Trigger On -
Address

If Address was configured for the Trigger On
setting, then the triggering address/addresses
must be configured.

1. If Trigger On was configured to

Address or Address/Data (I

2

C), press

Address on the bottom menu.

2. Press Addressing Mode to toggle

between 7 and 10 bit addressing
modes.

3. To choose a preset address as the

default address, press Choose
Preset
.

Address

Description

0000 000 0

General Call

0000 000 1

START Byte

0000 1XX X

Hs-mode

1010 XXX X

EEPROM

0000 001 X

CBUS

4. Press Apply Preset to set the default

address to the preset.

Note

Presets are not available for Trigger On
Address/Data.

5. Press Address from the side menu

to manually edit the triggering
address.

To edit the address, use the