Edwards Signaling B-KH Series User Manual
Page 2
Figure 2. Mounting the Remote Phone Signal
P-047550-1605 ISSUE 1
INSTALLATION
NOTE: Telecommunication wiring which is connected to the
B-KH series signal shall not extend outside the building
that the signal is contained in.
1.
Mount on any solid surface using the spacing template
provided (Figure 2).
2.
Connect one end of standard modular telephone line to tee
jack and the other end to the phone signal unit. Connect a
second standard modular telephone line from the tee jack to
the telephone. See Figure 3.
3.
Adjust volume of horn using the manual shutter. The shutter
on the horn provides variable attenuation up to 20 dB.
4.
Verify operability of unit. In the event of malfunction,
disconnect from phone to prevent possible damage to phone
system.
MAINTENANCE
CAUTION
This unit is not serviceable or repairable. Should the unit
fail to operate, contact the supplier for replacement.
If this product should fail to operate, disconnect it from the tele-
phone line and determine if the problem is in the telephone line or
the device. If this product is defective, discontinue its use and
obtain a replacement.
Figure 2. Spacing Template