Actuator switch, Required for each safety gate, Series circuit parallel circuit – Edwards Signaling 371-BT Series User Manual

Page 2

background image

Perpendicular

Actuation

Door

Actuation

Parallel Actuation

Best

Best

Not Recommended

Pivot Actuation

Good

The parallel actuation can result in on/off/on signal if the actuator passes by the
switch rather than coming to rest in proximity to it. This is NOT a recommended
configuration for safety interlock applications.

Figure 1

Figure 2

Mounting Configurations

Wiring Diagram for Category 3

Inputs shown with safety gates/guards in closed position. One Series 300-BT GuardSwitch

required for each safety gate.

Actuator

Switch

conduit

sensing face

sensing face

*300-BLT-

*Or other DPST GuardSwitch

(See the 300-BT Series installation instructions)

( – )

( + )

INT-03-230: 230V AC
INT-03-120: 120V AC
INT-03-024: 24V DC

R e q u i r e d F a s t o r
S l o w - A c t i n g F u s e :
( 2 5 0 V , 5 x 2 0 m m F )
I N T - 0 3 - 2 3 0 : 4 0 m A
I N T - 0 3 - 1 2 0 : 8 0 m A
I N T - 0 3 - 0 2 4 : 1 / 4 A

Required Fast or Slow-
Acting Fuses: 4A (250V,
5x20 mm F

W
H
T

B
L
K

R
E
D

B
L
U

*300-BLT-

W
H
T

B
L
K

R
E
D

B
L
U

Note – The LED on the BLT model will be ON when the guard is open

Fuses: 1 A (250 v)

Multiple DPST GuardSwitches – Shown with actuators in position, all guards closed.

The L.E.D of the BLT model will be on when the guard is open. If multiple guards

are open, L.E.D will be dimmer. The maximum number of GuardSwitches that can

be used is 50, although troubleshooting and line resistance must be considered.

(Do not exceed 30 Ohms of combined contact and line resistance. Each GuardSwitch

will have less than 0.5 Ohms of resistance.)

RESET

A

SAFE

AUX.

B

C

D

Safety Monitor Relay
INT-03

E

F

G

OUTPUTS

230 VAC

60 VDC

120 VAC

30 VDC

LOADS

*300-BLT-

W
H
T

B
L
K

R
E
D

B
L
U

Series Circuit

Parallel Circuit

+

L1

L2

1

2

X1 X2

Y1

Y2

N.O.

N.C.

S1

BLK

WHT

BLUE

RED

S2

S3

S4

CIR. 2

CIR. 1

*Circuits shown with magnet actuator away from switch.

S1

Normally open reed switch, closed when actuator is within 0.6"

S2, S3

Normally open reed switches, will close if misaligned or tampered with a
standard magnet

S4

Biased closed reed switch, open when actuator is between 0.3" and 0.6"

N.O. circuit: Black and white wires.
N.C. biased tamper circuit: Red and blue wires.

6. When mounting the switch on an ungrounded machine, ground the switch housing

by connecting your ground lead to one of the switch mounting screws.

GuardSwitch

TM

Series 300