Untitled, Ordering/electrical specifications, General specifications – Edwards Signaling 141 Series User Manual
Page 2

Ordering/Electrical Specifications
PART NUMBER
CONTACT
1
LOAD RATING
SWITCHING VOLTAGE
SWITCHING CURRENT
SENSE RANGE
2
BREAK RANGE
LEAD LENGTH
CONFIG.
MAXIMUM, AC/DC
MAXIMUM, AC/DC
MAXIMUM, AC/DC
NOMINAL
NOMINAL
NOMINAL
141-6Y-06M
N.O.
25VA/25W
120V @0.2A
120V @0.2A
0.7A @35V
1.0A @25V
1.0"(2.5cm)
1.6"(4.1cm)
6'(1.8m)
141-6Y-12J
N.O.
25VA/25W
120V @0.2A
120V @0.2A
0.7A @35V
1.0A @25V
1.0"(2.5cm)
1.6"(4.1cm)
12'(3.6m)
141-6Y-12M
N.O.
25VA/25W
120V @0.2A
120V @0.2A
0.7A @35V
1.0A @25V
1.0"(2.5cm)
1.6"(4.1cm)
12'(3.6m)
141-8Y-06M
N.O./
150VA/NA
120V @1.25A NA
1.25A
3
/NA
NA
1.0"(2.5cm)
1.2"(3.0cm)
6'(1.8m)
141-8Y-12M
N.O./
150VA/NA
120V @1.25A NA
1.25A
3
/NA
NA
1.0"(2.5cm)
1.2"(3.0cm)
12'(3.6m)
141-17N-12K
N.O.
100VA/100W
250V @0.4A
250V @0.4A
3.0 @34V
3.0 @34V
Switch Only
Switch Only
12'(3.6m)
141-17Y-06K
N.O.
100VA/100W
250V @0.4A
250V @0.4A
3.0 @34V
3.0 @34V
0.7"(1.8cm)
1.6"(4.1cm)
6'(1.8m)
141-17Y-12K
N.O.
100VA/100W
250V @0.4A
250V @0.4A
3.0 @34V
3.0 @34V
0.7"(1.8cm)
1.6"(4.1cm)
12'(3.6m)
141-18N-03M
N.O./
220VA/NA
220V @1.0A
NA
1.0A/NA
NA
Switch Only
Switch Only
3'(0.9m)
141-18N-12M
N.O./
220VA/NA
220V @1.0A
NA
1.0A/NA
NA
Switch Only
Switch Only
12'(3.6m)
141-18Y-03M
N.O./
220VA/NA
220V @1.0A
NA
1.0A/NA
NA
0.7"(1.8cm)
1.6"(4.1cm)
3'(0.9m)
141-18Y-06M
N.O./
220VA/NA
220V @1.0A
NA
1.0A/NA
NA
0.7"(1.8cm)
1.6"(4.1cm)
6'(1.8m)
141-18Y-12M
N.O./
220VA/NA
220V @1.0A
NA
1.0A/NA
NA
0.7"(1.8cm)
1.6"(4.1cm)
12'(3.6m)
141-Y
Actuator Only
Included with all switches unless otherwise noted.
Warning— Each electrical rating is an individual maximum and cannot be exceeded!
1
Configuration with actuator away from the switch
2
Proximity of ferrous materials usually reduces sense range — typically by 50%. The shape and type of material cause a wide diversity of effects.
Testing is required to determine actual sense range for specific applications.
3
Can withstand inrush surge up to 4 Amps. Volage Drop 1.5V. Minimum Switch Current 30mA. Maximum 10 switches in series.
File E 122942
LR89176
General Specifications
Enclosure
Kynar® Polyvinylidene Flouride
with sonic welded lid
Temperature Range
14
°
F to 150
°
F (-10
°
C to 65
°
C)
Environmental
Hermetically Sealed Contact Switch
Sealed in Polyurethane
NEMA Rating
1, 2, 3, 4, 4X, 5, 6, 12, 13
Protection Class
IP 67
Response Time
10 msec
Life Cycles
100,000 Under Full Load;
Up to 200,000,000 Under Dry Circuit
Lead Types/O.D.
18/2 SJTOW(M)/0.29" (0.74cm)
18/2 SJTOW(K)/0.30" (0.76cm)
22/2 Jacketed(J)/0.16" (0.40cm)
UL/CSA
All Models
Figure 2
Parallel Actuation
Not Recommended
Perpendicular
Actuation
Door
Actuation
Pivot Actuation
Best
Best
Good
Three configurations are appropriate for interlock applications. The parallel actuation
can result in on/off/on signal if the actuator passes by the switch rather than
coming to rest in proximity to it. This is NOT a recommended configuration for
interlock applications.
sensing face
sensing face
Figure 1
triac
output
triac
output
triac
output
triac
output
triac
output
triac
output
triac
output
P/N 1031295 • REV E • REB 17MAY13