Maintenance

Maintenance

Maintenance

Maintenance

Maintenance

Disassemble the unit as follows (Figure 5):

WARNING

To reduce the risk of ignition of hazardous atmo-
spheres and shock, keep assembly tightly closed
when circuits are energized.

1. Loosen the (3) guard screws and remove the guard.

2. Loosen the globe and ring assembly set screw. Insert

a suitable tool into the notches in the globe and ring

assembly and loosen the assembly by prying in a

counterclockwise direction. Remove the ring and

globe assembly.

3. Refer to Table 1 for the correct replacement catalog

number and replace the necessary part.

4. To replace, simply screw the unit on until it seats firmly

onto its gasket. Tighten the unit another 1/8 to 1/4

turn. Tighten the setscrew.

5. Reinstall the guard, where applicable, and secure using

the three supplied screws.

6. After the unit is assembled, apply power and make

sure the unit functions properly.