Edwards Signaling 103 Series User Manual
Page 2
Figure 1. Conduit Mounting (3/4" Shown)
Figure 2. Panel Mounting
P/N 3100414 ISSUE 1
Table 1. PLC Compatibility
Operating
Max. off state
Continuous
Surge
voltage
leakage current
on current
(inrush/duration)
Cat. No.
Volts
mA
mA
A/mSeconds**
103-RBA-G1
24V DC
5
65
0.070/8
103-RGA-G1
103-RBA-N5
120V AC
5
55
0.100/8
103-RGA-N5
*All AC volts at 60 Hz
** Amps/milliseconds
103I Series Chameleon
Visual Status Indicator
3/4" (19 mm) NPT
conduit (not supplied)
Power source wires
Wire Nuts
(not supplied)
Amber (DC hot or AC hot
for Amber LED activation)
Red (DC hot or AC hot
for Red LED activation)
Black (DC common) or White (AC neutral)
Blue or White with Green tracer
(DC hot or AC hot
for Blue or Green LED activation
(depending on model))
103I Series Chameleon
Visual Status Indicator
Gasket
(supplied)
Wire nuts
(not supplied)
Locking Nut -
1.3625" OD
(supplied)
Control panel
Amber (DC hot or AC hot
for Amber LED activation)
Red (DC hot or AC hot
for Red LED activation)
Black (DC common) or
White (AC neutral)
Blue or White with Green
Stripe (DC hot or AC hot
for Blue or Green LED activation
(depending on model))